200 Series: Double Hung & Single Hung

Casement Widnows
200 Double Hung & 203 Single Hung

200 Double Hung

  • 2 7/8 " flush frame depth
  • Bottom sash Double Tilts in for easy cleaning
  • Standard Sash Locks
  • Upper sash is removable making every unit a “drywall” unit
  • One piece sloped sill for improved drainage
  • Block and tackle balance system
  • Half screen standard
  • Full screen standard, half screen optional

Performance Data

Report # AI-01725-A & 110-7428-01
Air (a) Water (b) Wind Load (C) R Value Clear R Value Low-E/Argon
A3 B3 C3 2.04 2.86
ENERGY RATINGS AII106w-b   Clear -22 Low E Argon -6
Test Method: AAMA/NWWDA 101/I.S. 2-97 Size 44" X 60"       Performance Rating: H-R40
  Air Infiltration @ 1.57 PSF(25 MPH) Water Resistance @ 6 PSF Uniform Load @ 60 PSF
Measured .11 CFM/ FT. No Entry No Damage
Allowed <0.3 SCFM/ FT. No Entry No Damage
Thermal Performance & Solar Heat Gain
Test Method: NFRC 100 + NFRC 200-95
  U-Factor SHGC W/Out Grids Visible Transmittance W/Out Grids SHGC W/Grids Visible Transmittance W/Grids
Clear Glass 0.49 0.59 0.61 0.53 0.55
Low E Glass with Argon Gas 0.35 0.55 0.57 0.50 0.51

Minimum and Maximum Size: Single Units

Double Hung

Width Height Sq.Ft.
Min: 14” 22” 2.10
Max: 48” 78” 24.00

203 Single Hung

  • 2 7/8 “ flush frame depth
  • Bottom sash Double Tilts in for easy cleaning
  • Standard Sash Locks
  • Upper sash is removable making every unit a “drywall” unit
  • One piece sloped sill for improved drainage
  • Block and tackle balance system
  • Half screen standard
  • Bottom sash tilts in for easy cleaning
  • Upper sash is removable making every unit a “drywall” unit
  • Half screen standard

Performance Data

Report # AI-01725-C & 110-6156-01
Air (a) Water (b) Wind Load (C) R Value Clear R Value Low-E/Argon
A3 B3 C3 2.04 2.86
ENERGY RATINGS AII106w-b   Clear -22 Low E Argon -6
Test Method: AAMA/NWWDA 101/IS 2-97 Size 44" x 60"       Performance Rating: HR-40
  Air Infiltration @ 1.57 PSF(25 MPH) Water Resistance @ 6 PSF Uniform Load @ 60 PSF
Measured .11 CFM/ FT. No Entry No Damage
Allowed <0.375 SCFM/ FT. No Entry No Damage
Thermal Performance & Solar Heat Gain      
Test Method: NFRC 100 + NFRC 200-95
  U-Factor SHGC W/Out Grids Visible Transmittance W/Out Grids SHGC W/Grids Visible Transmittance W/Grids
Clear Glass 0.50 0.58 0.60 0.52 0.52
Low E Glass with Argon Gas 0.35 0.54 0.56 0.48 0.49

Minimum and Maximum Size: Single Units

Single Hung

Width Height Sq.Ft.
Min: 14” 22” 2.10
Max: 48” 78” 24.00